![OPTIMO Logo RGB Positive](https://pcp.structpim.com/media/1170/optimo-logo-rgb-positive.png?anchor=center&mode=crop&rnd=132548344710000000&width=115&height=0,https://pcp.structpim.com/media/1170/optimo-logo-rgb-positive.png?anchor=center&mode=crop&rnd=132548344710000000&width=230&height=0 2x)
Blechprofilroste LHD
F960160100Stahl
![OPTIMO-Grating-LHD-Steel-240-YP-F960160100-1.jpg](https://pcp.structpim.com/media/16284/optimo-grating-lhd-steel-240-yp-f960160100-1.jpg?anchor=center&mode=crop&rnd=132410637040000000&width=540&height=540,https://pcp.structpim.com/media/16284/optimo-grating-lhd-steel-240-yp-f960160100-1.jpg?anchor=center&mode=crop&rnd=132410637040000000&width=1080&height=1080 2x)
![OPTIMO-Grating-LHD-Steel-240-YP-F960160100-2.jpg](https://pcp.structpim.com/media/16285/optimo-grating-lhd-steel-240-yp-f960160100-2.jpg?anchor=center&mode=crop&rnd=132410637040000000&width=540&height=540,https://pcp.structpim.com/media/16285/optimo-grating-lhd-steel-240-yp-f960160100-2.jpg?anchor=center&mode=crop&rnd=132410637040000000&width=1080&height=1080 2x)
![Optimo Plank Grating Length Equals Span Direction](https://pcp.structpim.com/media/17681/optimo-plank-grating-length-equals-span-direction.jpg?anchor=center&mode=crop&rnd=132499992590000000&width=540&height=540,https://pcp.structpim.com/media/17681/optimo-plank-grating-length-equals-span-direction.jpg?anchor=center&mode=crop&rnd=132499992590000000&width=1080&height=1080 2x)
![OPTIMO-Grating-LHD-Steel-240-YP-F960160100-3.jpg](https://pcp.structpim.com/media/19329/optimo-grating-lhd-steel-240-yp-f960160100-3.jpg?anchor=center&mode=crop&rnd=132787341190000000&width=540&height=540,https://pcp.structpim.com/media/19329/optimo-grating-lhd-steel-240-yp-f960160100-3.jpg?anchor=center&mode=crop&rnd=132787341190000000&width=1080&height=1080 2x)
Technische Daten
- Rutschemmung: R11 = 27° > Neigung > 19° nach DIN 51130
- Verdrängungsraum: V10 nach DIN 51130
- Luftstrom: 2,4 - 3,7 %
- Lochungen: 6 mm
- Entwässerungslochungen: 6 mm
- C-C Teilung: 72 x 36 mm
- ballProof , ,
- Fire resistance: Critical temperature 550 °C
Downloads
-
Certificate
- IFA DGUV Test Certificate 1604091 - R11-V10 - OPTIMO Plank Grating LHD - Galvanised Steel.pdf IFA DGUV Test Certificate 1604091 - R11-V10 - OPTIMO Plank Grating LHD - Galvanised Steel.pdf https://pcp.structpim.com/media/17204/optimo-blechprofilroste-lhd-stahl-verzinkt-dguv-zertifikat.pdf
- OPTIMO LHD Physical Testing Report LHD Pattern.pdf OPTIMO LHD Physical Testing Report LHD Pattern.pdf https://pcp.structpim.com/media/17784/ukas-physical-testing-report-lhd-pattern.pdf
- Fire Protection Gratings LHD - Test Report By RISE SP Sweden.pdf Fire Protection Gratings LHD - Test Report By RISE SP Sweden.pdf https://pcp.structpim.com/media/18890/fire-protection-gratings-lhd-test-report-by-rise-sp-sweden.pdf
-
PDF Drawing
-
Video
- Fire Protection Gratings LHD® - Test by PcP.mp4 Fire Protection Gratings LHD® - Test by PcP.mp4 https://pcp.structpim.com/media/17719/fire-protection-gratings-lhd-test-by-pcp.mp4
- Fire Protection Gratings Type LHD® - Test by MFPA Leipzig.mp4 Fire Protection Gratings Type LHD® - Test by MFPA Leipzig.mp4 https://pcp.structpim.com/media/17717/fire-protection-gratings-lhd-test-by-mfpa-leipzig.mp4
- Fire Protection Gratings LHD® - Test by RISE Sweden.mp4 Fire Protection Gratings LHD® - Test by RISE Sweden.mp4 https://pcp.structpim.com/media/17304/fire-protection-gratings-lhd-test-by-rise-sweden.mp4
-
Brochure
- PCP Feuerschutztroste LHD Fur Brandschutz In Hochspannungsanlagen.pdf PCP Feuerschutztroste LHD Fur Brandschutz In Hochspannungsanlagen.pdf https://pcp.structpim.com/media/19065/pcp-feuerschutztroste-lhd-fur-brandschutz-in-hochspannungsanlagen.pdf
- Catalogue - OPTIMO Roste und Stufe.pdf Catalogue - OPTIMO Roste und Stufe.pdf https://pcp.structpim.com/media/19371/pcp-optimo-roste-und-stufe.pdf
-
Manual
-
Datasheet